The Memory Fill instruction fills N number of words at
address IN to the address OUT. N has a range of 1 to
FILL_N
ENO
255.
OUT
Error conditions that set ENO = 0: SM4.3 (run-time),
0006 (indirect address), 0091 (operand out of range)
226
Operands
LAD
Clear VW200 to VW218
FILL_N
EN
ENO
IN
N
OUT
VW200
FBD
FILL_N
EN
ENO
IN
OUT
VW200
N

Example of Fill Instructions for SIMATIC LAD, STL, and FBD

SIMATIC Instructions
Data Types
WORD
BYTE
WORD
STL
LD
I2.1
FILL
0, VW200, 10
Application
0
fill
VW200
VW202
VW218
. . .
0
0
0
9-113