Siemens SIMATIC S7-200 System Manual page 462

Hide thumbs Also See for SIMATIC S7-200:
Table of Contents

Advertisement

S7-200 Specifications
Table A-4
Specifications for CPU 224 DC/DC/DC and CPU 224 AC/DC/Relay (continued)
Description
Order Number
Input Features
Number of integrated inputs
Input type
Input Voltage
Maximum continuous permissible
Surge
Rated value
Logic 1 signal (minimum)
Logic 0 signal (maximum)
Isolation (Field Side to Logic Circuit)
Optical isolation (galvanic)
Isolation groups of
Input Delay Times
Filtered inputs and interrupt inputs
HSC clock input rate
Single Phase
Logic 1 level = 15 to 30 VDC
Logic 1 level = 15 to 26 VDC
Quadrature
Logic 1 level = 15 to 30 VDC
Logic 1 level = 15 to 26 VDC
Connection of 2 Wire Proximity Sensor
(Bero)
Permissible leakage current
Cable Length
Unshielded (not HSC)
Shielded
HSC inputs, shielded
Number of Inputs ON Simultaneously
40 C
55 C
Output Features
Number of integrated outputs
Output type
Output Voltage
Permissible range
Rated value
Logic 1 signal at maximum current
Logic 0 signal with 10 K Ω load
Output Current
Logic 1 signal
Number of output groups
Number of outputs ON (maximum)
Per group - horizontal mounting (maximum)
Per group - vertical mounting (maximum)
Maximum current per common/group
Lamp load
ON state resistance (contact resistance)
Leakage current per point
Surge current
Overload protection
A-18
CPU 224 DC/DC/DC
6ES7 214-1AD21-0XB0
14 inputs
Sink/Source (IEC Type 1)
30 VDC
35 VDC for 0.5 s
24 VDC at 4 mA, nominal
15 VDC at 2.5 mA, minimum
5 VDC at 1 mA, maximum
500 VAC for 1 minute
8 points and 6 points
0.2 to 12.8 ms, user-selectable
20 kHz
30 kHz
10 kHz
20 kHz
1 mA, maximum
300 m
500 m
50 m
14
14
10 outputs
Solid state-MOSFET
20.4 to 28.8 VDC
24 VDC
20 VDC, minimum
0.1 VDC, maximum
0.75 A
2
10
5
5
3.75 A
5 W
0.3 Ω
µ
10
A, maximum
8 A for 100 ms, maximum
No
S7-200 Programmable Controller System Manual
CPU 224 AC/DC/Relay
6ES7 214-1BD21-0XB0
14 inputs
Sink/Source (IEC Type 1)
30 VDC
35 VDC for 0.5 s
24 VDC at 4 mA, nominal
15 VDC at 2.5 mA, minimum
5 VDC at 1 mA, maximum
500 VAC for 1 minute
8 points and 6 points
0.2 to 12.8 ms, user-selectable
20 kHz
30 kHz
10 kHz
20 kHz
1 mA, maximum
300 m
50 m
50 m
14
14
10 outputs
Relay, dry contact
5 to 30 VDC or 5 to 250 VAC
-
-
-
2.00 A
3
10
4/3/3
4/3/3
8 A
30 W DC/200 W AC
0.2 Ω, maximum when new
-
7 A with contacts closed
No
A5E00066097-02

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents