10. STANDARD ADJUSTMENTS
10-9. Adjusting the position of the movable knife
3059B
5255Q
1. Open the top cover and tilt back the machine head.
2. Turn the pulley (1) by hand in the direction of the arrow to move the needle bar to its lowest position, and push the thread
trimming solenoid (2) as far as it will go.
3. With the collar (3) inserted into the groove of the thread trimmer cam (4), turn the pulley (1) by hand to set the driving lever
(5) to the reverse position (when the thread take-up (6) is close to its lowest position).
3129B
4. Loosen the two screws (7), and then remove the cover (8).
5. Loosen the bolt (9).
6. Move the movable knife connecting plate (11) back and forth to adjust so that the distance from the ridge on the right side
of the needle plate to the ridge on the movable knife (10) is 9.5 to 9.9 mm.
7. After tightening the bolt (9), check the above position once more.
59
<View from side of thread trimmer cam>
BAS-311H
Reverse position
5232Q 3128B
5233Q
3130B