6. USING THE OPERATION PANEL (ADVANCED OPERATIONS)

6-1. Setting memory switches

1
Change the mode to memory switch setting mode.
Menu indicator switches off, TEST indicator flashes
2
Select the memory switch that you would like to change
the setting for.
If you would like to display only the numbers of
memory switches that have been changed from default
settings
3
Change the memory switch parameters.
Apply the changed parameter setting.
4
Repeat steps 2 to 4 above to set each memory switch.
5
6
Exit setting mode.
All indicators switch off
TEST indicator switches off
6. USING THE OPERATION PANEL (ADVANCED OPERATIONS)
While pressing the TEST key, press the TENSION key.
・ The memory switch number will appear in the
PROGRAM No. display, and the setting value for that
memory switch number will appear in the menu display.
Press the
or
number.
While pressing the SELECT key, press the
(1).
・ The numbers of memory switches that have been
changed from default settings will appear in order.
Press the
or
・ The flashing display means that the setting has not yet been
applied.
・ You can make the initial setting appear in the display by
pressing the RESET key.
Press the ENTER key.
・ The menu display will change from flashing to
illuminated, and this means that the setting has been
applied.
・ If you press the
without pressing the ENTER key, you can cancel the
2414B
parameter changes.
Press the TEST key.
・ The changes will be memorized and the sewing
machine will switch to home position detection standby.
BAS-311H
key to select the memory switch
key to change the setting value.
or
key (1) or the TEST key
3094B 2421B
3095B
or
key
2423B
3096B
2404B