11. STANDARD ADJUSTMENTS
11-9. Adjusting the position of the movable knife
2574B
5255Q
1. Open the top cover and tilt back the machine head.
2. Turn the pulley (1) by hand to lower the needle bar to its lowest position, and push the thread trimmer solenoid (2) as far
as it will go.
3. With the collar (3) inserted into the groove of the thread trimmer cam (4), turn the pulley (1) by hand to set the driving lever
(5) to the reverse position (when the thread take-up (6) is close to its lowest position).
2909B
4. Loosen the bolt (7).
5. Move the thread trimming rod H (9) forward or back to adjust so that the ridge line on the movable knife (8) and reference
line (A) on the needle plate are aligned.
6. After tightening the bolt (7), check the above position once more.
59
<View from side of thread trimmer cam>
BAS-342G PS
5232Q 2921B
Reverse position
2908B
2210B