BY-PASS(OP A)
*1*3
*1*4
BY-PASS(OP B)
*1 The BY-PASS that is displayed as disabled in the BY-PASS SETTING menu (sec. 5-9-11) will not turn
on by setting the above to ON. In such case, the menu will be displayed as "*BYPASS(SDI1)". To
enable the BY-PASS, change associated settings in FS INPUT SELECT (sec. 5-6-1) and OUTPUT
ASSIGN (sec. 5-7-1).
*2 Although FREEZE is set to ON, the freeze function is disabled if SYNCHRO in section 5-9-1 "FS MODE
SET" is set to LINE, or AVDL. In such case, the menu will be displayed as "*FREEZE". To enable
FREEZE for INPUT FUNCTION, be sure to set SYNCHRO to FRAME.
*3 Shown only if FA-95AIO option is installed in option slot A
*4 Shown only if FA-95AIO option is installed in option slot B
*5 Event loading will load all settings.
*6 Shown only if FA-95ALA option is installed in option slot A
*7 Shown only if FA-95ALA option is installed in option slot B.
See section 14 "REMOTE" for details on pulse and level durations.
 OUTPUT FUNCTION
Function
NONE
FS1/FS2 FREEZE
FS1/FS2 VIDEO IN
AUDIO IN
REF IN
*1
FAN ALARM
*2
DC POWER 1
*2
DC POWER 2
FS1/FS2 SDI1
FS1/FS2 SDI2
FS1/FS2 COMPOSITE
*3
FS1/FS2 OP A
*4
FS1/FS2 OP B
FS1/FS2 KEYER
LOUD1, 2A CTRL
*5
*6
LOUD1, 2B CTRL
*1 FAN ALARM goes to low (active), if either one of two fans fails.
*2 Effective if the optional FA-95PS is installed.
*3 Effective if the optional FA-95AIO is installed in option slot A.
*4 Effective if the optional FA-95AIO is installed in option slot B.
*5 Effective if the optional FA-95ALA is installed in option slot A.
*6 Effective if the optional FA-95ALA is installed in option slot B.
Sets BY-PASS ON/OFF for FA-95AIO I/O in slots A&B.
Level
Shorted to GND:
OPEN:
NOTE
No function
FS1/FS2 FREEZE ON:
FS1/FS2 FREEZE OFF:
Signal present in FS1/FS2:
No signal present in FS1/FS2:
Signal present:
No signal present:
Signal present:
No signal present:
FAN failed:
FAN normal:
Power 1 failure:
Power 1 normal:
Power 2 failure:
Power 2 normal:
FS1/FS2 SDI1 input signal is selected:
FS1/FS2 SDI1 input signal is not selected:
FS1/FS2 SDI2 input signal is selected:
FS1/FS2 SDI2 input signal is not selected:
FS1/FS2 COMPOSITE input signal is selected: Low
FS1/FS2 COMPOSITE input signal is not selected:
FS1/FS2 OP A input signal is selected:
S1/FS2 OP A input signal is not selected:
S1/FS2 OP B input signal is selected:
S1/FS2 OP B input signal is not selected:
FS1/FS2 KEYER is enabled:
FS1/FS2 KEYER is disabled:
Each LOUDNESS CONTROL is set to ON
(LOUDNESS measurement is active):
Each LOUDNESS CONTROL is set to OFF
(LOUDNESS measurement is inactive):
146
BY-PASS ON
BY-PASS OFF
Description
Low
High (Open Collector)
Low
High (Open Collector)
Low
High (Open Collector)
Low
High (Open Collector)
Low
High (Open Collector)
Low
High (Open Collector)
Low
High (Open Collector)
Low
High (Open Collector)
Low
High (Open Collector)
High (Open Collector)
Low
High (Open Collector)
Low
High (Open Collector)
Low
High (Open Collector)
Low
High (Open Collector)