1.2 Elevator control and trim system

1.2.1

Control system

see diagram 1

1.2.2 Elevator deflections and tolerances

up:
down:
measured at 168 mm (6.61 in.) from hinge axis which is directly at the edge of
the cut out for the rudder
Measurement:
 Hold a measuring stick with one end on the floor, the stick must be vertical
when touching the elevator trailing edge.
 Set the elevator to zero by using a pattern. A drawing for the zero-pattern is
available from DG Flugzeugbau.
 Mark the 0-point on the stick.
 Then measure the up and down deflections according to the sketch.
1.2.3

Elevator stops

The elevator stops are located at the rear control column and can be adjusted
with a 10 mm open end wrench.
Issued: February 2011
Maintenance Manual DG-1000T
27°
u= 77 up to 79 mm
21°
d= 61 up to 63 mm
TN1000/18
(3.03 up to 3.11)
(2.40 up to 2.48)
u
d
1.2