1.2 Elevator control and trim system
1.2.1
Control system
see diagram 1
1.2.2 Elevator deflections and tolerances
up:
down:
measured at 168 mm (6.61 in.) from hinge axis which is directly at the edge of
the cut out for the rudder
Measurement:
Hold a measuring stick with one end on the floor, the stick must be vertical
when touching the elevator trailing edge.
Set the elevator to zero by using a pattern. A drawing for the zero-pattern is
available from DG Flugzeugbau.
Mark the 0-point on the stick.
Then measure the up and down deflections according to the sketch.
1.2.3
Elevator stops
The elevator stops are located at the rear control column and can be adjusted
with a 10 mm open end wrench.
Issued: February 2011
Maintenance Manual DG-1000T
27°
u= 77 up to 79 mm
21°
d= 61 up to 63 mm
TN1000/18
(3.03 up to 3.11)
(2.40 up to 2.48)
u
d
1.2