MAINTENANCE

PREVENTATIVE MAINTENANCE SCHEDULE
WARNING: The safety level of the equipment can only be maintained if it is regularly inspected for damage
and wear. Immediately replace defective parts and do not use the equipment until all repairs have been
completed and thoroughly tested.
Weekly
1st Month
Monthly
Biannually
Check to ensure that the machine is in safe proper working order.
Wipe off sweat with a soft towel or cloth.
Check the crank arms for no looseness.
Check to ensure both screws that attach the Recoilers to the Frame are torqued
to 20 ft-lbs (27 Nm).
Check Footpads and Arms for excessive movement with the Emergency Brake
engaged.
Clean external surfaces using warm water and a soft cloth, especially around
the areas that come in contact with sweat.
Do not use household or industrial cleaners as they can destroy the protective
finish of the paint.
For deeper cleaning, use only mild dish washing soap, followed by an
automotive treatment such as Meguiar's Quik Detailer Mist and Wipe.
Check to ensure all screws, bolts, and nuts are tight.
Check the crank arms for no looseness. Re-torque each bolt to 35 ft-lbs (47 Nm).
Check Handle Grips, Safety Straps, and Foot Straps and replace if worn.
The low battery signal ("LO-BA") will appear on the computer display when
it is time to replace the batteries. FOR ESTABLISHMENTS WITH MULTIPLE
MACHINES, REPLACEMENT OF ALL COMPUTER BATTERIES AT THE SAME
TIME IS RECOMMENDED (two D batteries per machine). See "Computer Battery
Replacement" on page 16.
Apply wax to protect the paint finish:
1.
Wipe down and thoroughly clean machine prior to applying wax.
2.
Use an easily applied automotive treatment such as Meguiar's Quik Detailer
Mist and Wipe.
3.
Target areas that come in contact with sweat, most vulnerable to rust.
NOTE: Failure to apply a coat of wax to high-sweat areas at least twice annually
will decrease paint and frame life due to corrosion and will void the warranty.
Apply lubricant to the Adjustment Knobs:
1.
Unscrew Adjustment Knobs from the Arm Tube.
2.
Clean threads with a lint-free cloth.
3.
Apply a moderate amount of lubricant to the threads.
NOTE: Both the threaded stud and the threaded insert nut are stainless steel. It
is critical to keep the threads lubricated with a heavy grease (preferably white or
clear in color), such as Acculube #2 or any compound with equivalent anti-wear
and corrosion resistant properties.