PREVENTATIVE MAINTENANCE SCHEDULE
CAUTION: THE HIGHEST LEVEL OF EQUIPMENT SAFETY CAN ONLY BE ENSURED IF THE EQUIPMENT IS
REGULARLY INSPECTED FOR DAMAGE AND WEAR. Immediately replace damaged, worn, or broken parts. Do not
use the Air300 Leg Extension Pro until all repairs have been completed and tested by a Keiser-certified technician.
Daily
Weekly
Monthly
Quarterly
Annually and
other Required
Maintenance
IMPORTANT: Do not use household or industrial cleaners as they contain caustic chemicals that can destroy the paint finish
and cause corrosion. Use only mild soap/detergent (neutral, non-caustic) to clean.
Contact Keiser Customer Support for replacement parts order, or for any matters regarding the safe operation of your
Air300 Leg Extension Pro (see back cover for contact information).
Check for safe and proper function of the equipment (perform "Proper Operation
Check," page 11).
Clean the chrome and paint where applicable.
Wipe down the equipment with a clean cloth. If necessary, use water and mild soap
(neutral, non-caustic). Target areas that come in contact with sweat. Wipe dry the
equipment.
Check parts most susceptible to wear are not damaged or broken:
– Upholstery, Belt/Linkage System, Thumb Buttons, and Hand Grips.
Wax chrome and paint where applicable; wax upholstery.
Clean Hand Grips.
Inspect Air Line Filter.
Check externally visible screws are fastened properly with no looseness.
Clean and lubricate Cylinder Rods.
Inspect Air Line for kinks, tears, or breaks.
Inspect Frame for any weakening in weld areas, and other connected areas.
Lubricate Pivot Bushings.
Inspect Exhaust Mufflers and Air Filter for discoloration; replace if necessary.
Verify compressor(s) cycle on/off between 100-120 psi (6.89–8.27 bar).
For complete instructions, see page 17 "Annual Maintenance."
Battery Replacement. The low battery signal ("Lo-bA") will appear on the Power Display
when it is time to replace the batteries. Refer to page 16 "Battery Replacement" for
complete instructions.
NOTE: Your Keiser Air Compressor (not included with your Air300 Leg Extension Pro)
requires basic annual maintenance. Contact Keiser Customer Support for Air Compressor
operator manual or download at keiser.com/support (search: Air Compressor manuals).