CALIBRATING YOUR KEISER M SERIES EQUIPMENT
Procedure for software version U406 and above
Be sure to read all steps very closely before beginning. You have 25 seconds to go from
STEP 2 to STEP 9. After 25 seconds the computer will exit calibration mode and you must
allow it to shutdown before attempting to calibrate again. All work is done from the left
side of the machine, except on the M5, the work is done from the right and the plastic
cover must be removed.
STEP 1
Move the red shifter handle all the
way down.
Note: If you are unsure of your software
version, check the version by removing the
batteries for at least 20 seconds. Reinstall
the batteries and watch the display during
start-up for "U###". Allow the computer to
go to sleep before continuing to step 2.
STEP 2
Slowly rotate the pedal until the
computer turns on. Once it comes
on, continue turning for one-half
revolution then stop the crank
arm. Zeroes will appear on the
time slot on the display as shown
to the right.
STEP 3
Slide your red calibration tool onto
the flywheel as shown.
555512_D
1 ROTATION ONLY
Turns on Computer

Advertisement

loading

Summary of Contents for Keiser M Series

  • Page 1 CALIBRATING YOUR KEISER M SERIES EQUIPMENT Procedure for software version U406 and above Be sure to read all steps very closely before beginning. You have 25 seconds to go from STEP 2 to STEP 9. After 25 seconds the computer will exit calibration mode and you must allow it to shutdown before attempting to calibrate again.
  • Page 2 CALIBRATING YOUR KEISER M SERIES EQUIPMENT Procedure for software version U406 and above STEP 4 Pull calibration tool upward magnet housing. STEP 5 Turn the magnet housing counter/anti-clockwise and allow the magnets to rotate into your calibration tool. The magnets must align with the...
  • Page 3 CALIBRATING YOUR KEISER M SERIES EQUIPMENT Procedure for software version U406 and above STEP 7 Slide the calibration tool from the magnet housing. STEP 8 1 ROTATION ONLY Remove calibration tool from the flywheel. Until the computer shows 0:01 in the time row...
  • Page 4 Note: If you receive an error symbol “Err#” on the display please allow the computer to go to sleep then begin the calibration process again from Step 1. If the problem continues, note the error number that appeared on your display and contact Keiser service at 1-800-888-7009 or via email at service@keiser.com.