Mounting an EX4500 Switch

Related
Documentation

Mounting an EX4500 Switch on Two Posts in a Rack or Cabinet

126
Rack Requirements on page 74
Cabinet Requirements on page 75
Clearance Requirements for Airflow and Hardware Maintenance for EX4500 Switches
on page 76
You can mount an EX4500 switch:
On two posts in a 19-in. rack or cabinet by using the mounting brackets provided with
the switch.
On four posts in a 19-in. rack or cabinet by using the separately orderable four-post
rack-mount kit.
In a position recessed 2 in. from the front of a 19-in. rack or cabinet by using the
separately orderable four-post rack-mount kit. You can mount the switch in this
recessed position on four-post racks and cabinets.
The holes in the mounting brackets are placed at 1 U (1.75 in. or 4.45 cm) apart so that
the switch can be mounted in any rack or cabinet that provides holes spaced at that
distance.
See the Related Documentation for detailed descriptions of the various rack or cabinet
mounting options.
Mounting an EX4500 Switch on Two Posts in a Rack or Cabinet on page 126
Mounting an EX4500 Switch on Four Posts in a Rack or Cabinet on page 129
Mounting an EX4500 Switch in a Recessed Position in a Rack or Cabinet on page 132
Connecting Earth Ground to an EX Series Switch on page 135
You can mount an EX4500 switch on two posts of a 19-in. rack (either a two-post or a
four-post rack) or a 19-in. cabinet by using the mounting brackets provided with the
switch. (The remainder of this topic uses "rack" to mean "rack or cabinet.")
You can mount the switch on four posts of a four-post rack by using the mounting brackets
provided with the separately orderable four-post rack-mount kit. See
EX4500 Switch on Four Posts in a Rack or Cabinet" on page
Before mounting the switch on two posts in a rack:
Verify that the site meets the requirements described in
for EX4500 Switches" on page
Place the rack in its permanent location, allowing adequate clearance for airflow and
maintenance, and secure it to the building structure.
"Site Preparation Checklist
67.
Copyright © 2017, Juniper Networks, Inc.
"Mounting an
129.