a. If the tension is not within specification, repeat the adjustment process.
b. If the tension is within specification, continue procedure.
8. Torque the drive motor mount bolts to 204 in-lbs (17 ft-lbs, 23 N-m).
9. Plug in the power cord and switch the input power ON.
10. Run the treadmill speed at 3 mph for 1 minute.
11. Switch the power OFF and disconnect power.
12. Measure and verify that the tension measurement is within the Range Limit spe-
cification, see Drive Belt Tension Specification table. Note that there is a separate
Range Limit specification for New and Used belt installations.
a. If the belt tension is not within the Range Limit specification, repeat the tension
adjustment procedure.
b. If the belt tension is within the Range Limit specification, continue procedure.
13. Re-install hood.
14. Connect and Switch the input power ON.
15. Verify operation and return to service.