 Video Output Status
Item
Display
1080/59i
1080/50i
720/59p
720/50p
SDI Out 1/2
1080/23PsF
1080/24PsF
1080/59p
1080/50p
BY-PASS
Disable
SDI Out 3/4
Same as above
Composite Out
BY-PASS
Disable
1080/59i
1080/50i
Component
720/59p
*1
Out
720/50p
1080/23PsF
1080/24PsF
BY-PASS
Disable
*1 Shown if the FA-95AIO option is installed.
 Unit Status
Item
Display
Unit Name
FA-9500
Normal
FAN1
Stopped
Normal
FAN2
Stopped
Normal
*1
Power1
Abnormal
Normal
*1
Power2
Abnormal
*1 : Displays "-------" if the optional FA-95PS is not installed.
525/60
625/50
Displays the video format of the SDI1 output signal.
Displays "BY-PASS" if the function is enabled.
Displays "Disable" if there is no signal output.
Displays the video format of the SDI2 output signal.
Displays "BY-PASS" if the function is enabled.
Displays "Disable" if there is no signal output.
Displays the video format of the COMPOSITE output signal.
525/60
Displays "Disable" if there is no signal output.
625/50
Displays "PAL-M" if 9-4-1 PAL-M Mode Set is enabled, and
the format setting for the converted output video signal under
Composite Output Setting in the 9-2-11 Output Select menu
PAL-M
is 525/60.
Loss
525/60
625/50
Displays the video format of the Component output signal.
Displays "BY-PASS" if the function is enabled.
Displays "Disable" if there is no signal output.
Output signal format will be 525/60, 625/50, or PAL-M if the
Component output is set to Y/C mode.
PAL-M
Displays the unit name. The default setting is "FA-9500".
To change the unit name, see Unit Name in section 9-6-1
"Event Control"
Displays the status of FAN1.
Normal: Operating normally.
Stopped: FAN1 has stopped.
Turn the unit power off, and contact your dealer if a
replacement is needed.
Displays the status of FAN2.
Normal: Operating normally.
Stopped: FAN2 has stopped.
Turn the unit power off, and contact your dealer if a
replacement is needed.
Displays the status of DC POWER1.
Normal: The power supply is normal.
Abnormal: DC POWER1 has failed.
A power failure has occurred. Although the unit is working
properly, It is recommended that the power supply unit be
replaced. Contact your dealer if a replacement is necessary.
Displays the status of DC POWER2.
Normal: The power supply is normal.
Abnormal: DC POWER2 has failed
A power failure has occurred. Although the unit is working
properly, It is recommended that the power supply unit be
replaced. Contact your dealer if a replacement is necessary.