Error code
Parameter
26
Reference speed
H 2
27
Measured variable
H
28
Time base for velocity measurement
H
29
Increments per unit
H
2A
Counter low limit
•
H
Counter high limit
•
2B
Comparison value 0
•
H
Comparison value 1
•
2C
Signal evaluation
H
2D
Set output
H
2E
Setting function of the DI
•
H
Operating mode
•
3A
Count direction for synchronization
H 3
Only for "Counting" operating mode
1
Only for "Position input for Motion Control" operating mode
2
Only for "Fast Mode" operating mode
3
Technology module TM PosInput 1 (6ES7138-6BA00-0BA0)
Manual, 04/2016, A5E33015755-AC
Interrupts/diagnostic messages
Validation criteria
Less than minimum value
•
Higher than maximum value
•
Invalid value
Invalid value
Invalid value
Counter low limit >= Counter high limit
Comparison value 0 >= Comparison value 1
Invalid value
"Between comparison value 0 and 1" configured for DQ0
•
"Not between comparison value 0 and 1" configured for DQ0
•
"Between comparison value 0 and 1" configured for DQ1, but
•
for DQ0 "Use by user program" not configured.
"Not between comparison value 0 and 1" configured for DQ1,
•
but for DQ0 "Use by user program" not configured.
"Capture" configured in the "Measuring" operating mode
Invalid value
5.2 Parameter validation error