Parameter
Bit number LSB of the position
value
Bit number MSB of the position
value
Hardware interrupt:Change of
direction
1
Hardware interrupt:Comparison
event for DQ0 occurred
1
Hardware interrupt:Comparison
event for DQ1 occurred
1
Hardware interrupt:Zero point
Hardware interrupt: New Capture
value available
1
Set output
Substitute value for DQ
1
Count direction of the DQ func-
tion
1
Pulse duration [ms/10]
1
Technology module TM PosInput 1 (6ES7138-6BA00-0BA0)
Manual, 04/2016, A5E33015755-AC
Value range
0...38
1...39
Deactivated
Activated
Deactivated
Activated
Deactivated
Activated
1
Deactivated
Activated
Deactivated
Activated
Use by user program
Between comparison value and high
limit
Between comparison value and low
counter limit
Between comparison value 0 and 1
Not between comparison value 0
and 1
At comparison value for a pulse dura-
tion
After set command from CPU until
comparison value
Digital output without function
0
1
Up
Down
In both directions
0...65535
Configuring/address space
Default setting
0
12
Deactivated
Deactivated
Deactivated
Deactivated
Deactivated
DQ0, DQ1: Between
comparison value and
high limit
(Fast Mode: Digital output
without function)
4
DQ0, DQ1: 0
In both directions
5000 (corresponds to
0.5 s)
4.4 Parameters
Re-
configuration
in RUN
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
45