Mounting an EX3200 Switch on Four Posts in a Rack or Cabinet

114
Ensure that the other holes in the mounting brackets are aligned with the holes in the
5.
side panels. Insert a screw in each hole and tighten the screws.
Have one person grasp both sides of the switch, lift the switch, and position it in the
6.
rack, aligning the mounting bracket holes with the threaded holes in the rack or cabinet
rail. Align the bottom hole in both the mounting brackets with a hole in each rack rail,
making sure the chassis is level. See

Figure 26: Mounting the Switch on Two Posts in a Rack

Mounting rack
Have a second person secure the switch to the rack by using the appropriate screws.
7.
Tighten the screws.
Ensure that the switch chassis is level by verifying that all screws on one side of the
8.
rack are aligned with the screws on the other side.
Connecting Earth Ground to an EX Series Switch on page 123
Connecting AC Power to an EX3200 Switch on page 129
Connecting DC Power to an EX3200 Switch on page 131
Connecting and Configuring an EX Series Switch (CLI Procedure) on page 145
Connecting and Configuring an EX Series Switch (J-Web Procedure) on page 148
Mounting an EX3200 Switch in a Recessed Position in a Rack or Cabinet on page 118
Rack-Mounting and Cabinet-Mounting Warnings on page 220
You can mount an EX3200 switch on four posts of a 19-in. rack or cabinet by using the
separately orderable four-post rack-mount kit. (The remainder of this topic uses "rack"
to mean "rack or cabinet.")
Figure 26 on page
114.