Cleaning and maintenance
36/54
5.8
Instructions for replacing the lamps
DANGER!
UV radiation!
The lamps' effect decreases over the course of time. Danger
of skin and eye injuries or skin diseases!
–
As such, the replacement intervals specified in the
maintenance plan must be adhered to.
5.8.1
Low pressure lamps
Replace faulty UV low pressure lamps immediately.
Always replace the entire set of lamps after the specified operating time.
–
Turn 90° and carefully remove from the socket.
–
UV and Beauty Light lamps have a reflector which directs the light out-
wards. The lamps must be mounted in such a way that the rear side of
the reflector is located on the device side.
–
Push the pins vertically into the socket from above.
–
When fitting the lamps, ensure that they are in the correct sequence.
NOTE:
The UV low pressure lamps do not fit in the coded lamp
sockets.
Non coded socket:
Coded socket: