11.2 Time output management menu

Programming by PC software allows the time zone differential of each output
to be set with respect to the local time.
This menu can be used to view all the time outputs, modify their status (Start/
Stop), configure the DHF distribution in Init mode and configure the "impulse"
and "D1D2" distribution.
This menu allows you also to configure the impulse output (Impuls 01) to
provide TBT 24VDC (0,5A) power supply.
To go to the SIGMA time output management
menu, validate the option in the technician
menu with the
The following screen is displayed :
On this screen you can start or stop the NTP
distribution. The programming is carried out
by software. See NTP programming in appendix 1, page 61.
Important: the NTP distribution service must be started first from the PC
software.
Validate with the
screen is displayed :
You can view the different options and
change the values using the
You can go through the different outputs by
validating using the
The 3 outputs (Impulse 01, Afnor 02 and
DHF03) are not programmable with a time
zone differential.
The placing of a DHF output in "INIT" status
is active for 4 hours before return to START
mode (The init mode display is alternating with the normal display during this
period).
This menu can be used to set the power of the DHF output with a choice of
25mW / 125mW (by default) / 500mW and assign the system address from 1
to 4 (2 by default).
36
key,
key. The following
and
key.
Time outputs
IP setting
NTP :
START
D1D2 minute:06s
START
00:00
keys.
Afnor 02: START ú
DHF
03 :
125mW channel:2 ok
ok
õ
ú
ok
ú
ok
ok
INIT
ú