number is between 0-511 (usually 0 & 1 are equal to 1).
5. The end of the DMX 512 system should be terminated to reduce signal errors.
6. 3 pin XLR connectors are more popular than 5 pins XLR.
3 pin XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+)
5 pin XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+), Pin4, Pin5 not used.

6.2 Address Setting

If you use a universal DMX controller to control the units, you have to set DMX address from 1 to 512
so that the units can receive DMX signal.
Press the MENU button to enter menu mode, select DMX Functions, press the ENTER button to
confirm, use the UP/DOWN button to select DMX Address, press the ENTER button to confirm, the
present address will blinking the display, use the UP/DOWN button to adjust the address from 001 to
512, press the ENTER button to store. Press the MENU button back to the last menu or idling let the
unit idle one minute to exit menu mode.
Please refer to the following diagram to address your DMX512 channel for the first 4 units.
Channel mode
17 channels
20 channels

6.3 DMX 512 Configuration

Please refer to below configurations to control the fixtures
Attentions:
1. The unit will maintain the last condition until reset if you cut-off the DMX signal.
2. For the channel Function, keep the value for about 5 seconds, then the corresponding function
will take into effect.
17 Channels (Mode 1):
CHANNEL
1
Unit 1
Address
1
1
VALUE
000-255
Unit 2
Unit 3
Address
Address
18
21
FUNCTION
PAN
0 °  540°
18A
Unit 4
Address
35
52
41
61