Operations Between Mst Regions - Cisco Catalyst 2950 Software Configuration Manual

Hide thumbs Also See for Catalyst 2950:
Table of Contents

Advertisement

Understanding MSTP

Operations Between MST Regions

If there are multiple regions or legacy IEEE 802.1D switches within the network, MSTP establishes and
maintains the CST, which includes all MST regions and all legacy STP switches in the network. The
MST instances combine with the IST at the boundary of the region to become the CST.
The IST connects all the MSTP switches in the region and appears as a subtree in the CST that
encompasses the entire switched domain. The root of the subtree is the IST master. The MST region
appears as a virtual switch to adjacent STP switches and MST regions.
Figure 15-1 shows a network with three MST regions and a legacy IEEE 802.1D switch (D). The IST
master for region 1 (A) is also the CST root. The IST master for region 2 (B) and the IST master for
region 3 (C) are the roots for their respective subtrees within the CST. The RSTP runs in all regions.
Figure 14-1
Legacy 802.1D
Figure 14-1
instances can be different from that of the IST for the same region.
Only the CST instance sends and receives BPDUs, and MST instances add their spanning-tree
information into the BPDUs to interact with neighboring switches and compute the final spanning-tree
topology. Because of this, the spanning-tree parameters related to BPDU transmission (for example,
hello time, forward time, max-age, and max-hops) are configured only on the CST instance but affect all
MST instances. Parameters related to the spanning-tree topology (for example, switch priority, port
VLAN cost, port VLAN priority) can be configured on both the CST instance and the MST instance.
MSTP switches use version 3 RSTP BPDUs or IEEE 802.1D STP BPDUs to communicate with legacy
IEEE 802.1D switches. MSTP switches use MSTP BPDUs to communicate with MSTP switches.
Catalyst 2950 and Catalyst 2955 Switch Software Configuration Guide
14-4
MST Regions, IST Masters, and the CST Root
D
B
IST master
MST Region 2
does not show additional MST instances for each region. Note that the topology of MST
IST master
A
and CST root
MST Region 1
Chapter 14
Configuring MSTP
C
IST master
MST Region 3
78-11380-12

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for: