Chapter 3
Configuring Catalyst 2955 Switch Alarms
Use the no alarm facility fcs-hysteresis command to set the FCS error hysteresis threshold to its default
value.
Note
The show running config command displays any FCS error hysteresis that is not the default value.
This example shows how to set the FCS error hysteresis at 5 percent.
Switch(config) # alarm facility fcs-hysteresis 5

Configuring Alarm Profiles

This section describes how to configure alarm profiles on your switch. It contains this configuration
information:

Creating or Modifying an Alarm Profile

You can use the alarm profile global configuration command to create an alarm profile or to modify an
existing profile. When you create a new alarm profile, none of the alarms are enabled.
The only alarm enabled in the defaultPort profile is the Port is not Operating alarm.
Note
Beginning in privileged EXEC mode, follow these steps to create an alarm profile:
Command
Step 1
configure terminal
Step 2
alarm profile name
Step 3
alarm alarm-id
Step 4
notifies alarm-id
Step 5
relay-major alarm-id
relay-minor alarm-id
Step 6
syslog alarm-id
Step 7
end
Step 8
show alarm profile name
Step 9
copy running-config startup-config (Optional) Save your entries in the configuration file.
To delete an alarm profile, use the no alarm profile name global configuration command.
78-11380-12
Creating or Modifying an Alarm Profile, page 3-9
Attaching an Alarm Profile to a Specific Port, page 3-10
Purpose
Enter global configuration mode.
Create the new profile or identify an existing profile, and then enter alarm
profile configuration mode.
Add or modify alarm parameters for a specific alarm (see
values are 1 to 4. You an enter more than one alarm ID separated by a space.
(Optional) Configure the alarm to send an SNMP trap to an SNMP server.
(Optional) Configure the alarm to send an alarm trap to the major relay.
(Optional) Configure the alarm to send an alarm trap to the minor relay.
(Optional) Configure the alarm to send an alarm trap to a syslog server.
Return to privileged EXEC mode.
Verify the configuration.