GE P741 Technical Manual page 262

Busbar differential protection relay
Table of Contents

Advertisement

P74x/EN PL/Na7
(PL) 7-28
DDB
Relay
No.
P742
604
CBF I> Start B
P742
605
CBF I> Start C
P742
606
CBF I> Start N
P742
700
Relay condit 01
P742
715
Relay condit 16
P742
923
Int. Node 1
P742
1023
Int. Node 101
P742
1024
VIRTUAL INPUT
1
P742
1087
VIRTUAL INPUT
64
P742
1152
Quality VIP1
P742
1215
Quality VIP64
P742
1280
PubPres VIP 1
P742
1343
PubPres VIP 64
1.8.2
Sorted by DDB name:
DDB
Relay
No.
P742
308
50BF Disabled
P742
311
50BF Disabled
PL
P742
379
87BB Earth Fault
P742
376
87BB Fault Ph A
P742
377
87BB Fault Ph B
P742
378
87BB Fault Ph C
P742
254
Acq Error 3Io
P742
270
All Prot Blocked
P742
358
Any Trip
P742
143
Aux Volt Superv
P742
486
Backup Setting
P742
469
Battery Fail
P742
290
BF Trip Request
P742
298
BFTripNoRequest
P742
174
Breaker failure
P742
123
CB Aux. 3ph(52a) PSL Output
P742
124
CB Aux. 3ph(52b) PSL Output
P742
344
CB Aux. 52a
P742
345
CB Aux. 52b
P742
125
CB Aux. A (52a)
P742
126
CB Aux. A (52b)
P742
127
CB Aux. B (52a)
English Text
Type
PSL Output
Signal
PSL Output
Signal
PSL Output
Signal
OUTPUT_CON
OUTPUT_CON
GOOSEIN
GOOSEIN
PSL Input Signal
PSL Input Signal
PSL Input Signal
PSL Input Signal
English Text
Type
PSL Input Signal
PSL Output
Signal
PSL Output
signal
PSL Output
signal
PSL Output
signal
PSL Output
signal
PSL Input Signal
PSL Input Signal
PSL Input Signal
PSL Output
Signal
PSL Input Signal
PSL Input Signal
PSL Input Signal
PSL Input Signal
PSL Input Signal
Signal
Signal
PSL Input Signal
PSL Input Signal
PSL Output
Signal
PSL Output
Signal
PSL Output
Signal
Source
50BF Protection
Phase B overcurrent CBF Dead Pole Start
50BF Protection
Phase C overcurrent CBF Dead Pole Start
50BF Protection
Neutral overcurrent CBF Dead Pole Start
Output Conditioner
Input to Relay Output Conditioner 1
Output Conditioner
Input to Relay Output Conditioner 16
Can be created automatically by the PSL
Can be created automatically by the PSL
GOOSE Input
Virtual Input 1
Command
Allows binary signals that are mapped to virtual
inputs to interface into PSL
GOOSE Input
Virtual Input 64
Command
Allows binary signals that are mapped to virtual
inputs to interface into PSL
PSL
Validation of the virtual input 1 (signal correct).
PSL
Validation of the virtual input 64 (signal correct).
PSL
Publishing presence of virtual input 1: indicates
virtual input 1 presence.
PSL
Publishing presence of virtual input 64:
indicates virtual input 64 presence.
Source
Commissioning
PU in 50BF blocked mode Alarm
Commissioning
To switch the PU in 50BF blocked mode
PSL
87BB earth Fault detected
PSL
87BB Phase Fault detected in phase A
PSL
87BB Phase Fault detected in phase B
PSL
87BB Phase Fault detected in phase C
Relay Integrity
Sample acquisition error: 3 x Io <> In
Commissioning
All the protections (CU & PU) disabled
All Protections
Any Trip (Logical OR of ddbs:
0, 1, 2, 168, 169, 170, 171, 256, 261)
PSL (Scheme
Auxiliary voltage supervision (To freeze the
Integrity)
CB/Isolators position)
InterMiCOM
Backup setting Alarm
This is an alarm that is ON if any setting fail
during the setting changing process. If this
happens, the relay will use the last known good
setting.
Relay Integrity
Front panel Battery Failure
50BF Protection
External or internal Breaker failure trip order
request (50BF) Logical OR of DDB 122, 172
and 173
50BF Protection
Complement of ddb 290
50BF Protection
Circuit Breaker Fail Alarm
Logical OR of DDB 172 to 173
PSL
52-A (CB closed) CB Auxiliary Input (3 phase)
PSL
52-B (CB open) CB Auxiliary Input (3 phase)
CB Monitoring
ddb 123 or Logical OR of ddb 125 and 127 and
129
CB Monitoring
ddb 124 or Logical AND of ddb 126 and 128
and 130
PSL
52-A (CB closed) CB Auxiliary Input (phase A)
PSL
52-B (CB open) CB Auxiliary Input (Phase A)
PSL
52-A (CB closed) CB Auxiliary Input (phase B)
Programmable Logic
MiCOM P741, P742, P743