Specifications - Kenmore 795.69292.902 Service Manual

Table of Contents

Advertisement

1. SPECIFICATIONS

1-1 DISCONNECT POWER CORD BEFORE SERVICING
IMPORTANT RECONNECT ALL GROUNDING DEVICES.
All parts of this appliance capable of conducting electrical current are grounded. If grounding wires, screws, straps, clips,
nuts or washers used to complete a path to ground are removed for service, they must be returned to their original position
and properly fastened.
1-2 IMPORTANT NOTICE
This information is intended for use by individuals possessing adequate backgrounds of electrical, electronic and
mechanical experience. Any attempt to repair a major appliance may result in personal injury and property damage. The
manufacturer or seller cannot be responsible for the interpretation of this information, nor can it assume any liability in
connection with its use.
1-3 ELECTRICAL SPECIFICATIONS
Temperature Control (Position: MID) .................................................................................................................... -6°F to +8°F
Defrost Control ......................................................................................................................................................... Automatic
Defrost Thermostat ........................................................................................................................................................... 50°F
Electrical Rating: 115VAC, 60Hz ..................................................................................................................................... 1 -5A
Maximum Current Leakage ............................................................................................................................................ 0.5mA
Maximum Ground Path Resistance ......................................................................................................................... 0.14Ohms
Energy Consumption ..............................................................................................................19cuft 396KWh/yr (Energy star)
1-4 NO LOAD PERFORMANCE
Control Position: MID/MID
And ambient of:
Fresh Food, °F .......................................................33°F to 41°F ............................................................................33°F to 41°F
Frozen Food, °F ......................................................-4°F to +4°F ............................................................................-4°F to +4°F
Percent Running Time ..............................................25% - 35% ...............................................................................45% - 60%
1-5 REFRIGERATION SYSTEM
Minimum Compressor Capacity Vacuum .......................... 21 in Clearance must be provided at top, sides and rear of the
Minimum Equalized Pressure
@ 70°F ...........................................................49PSIG AT TOP ..............................................................................1in
@ 90°F ...........................................................56PSIG AT SIDES .....................................................................1/18 in
Refrigerant R134a .......................................................... 4.2 Oz AT REAR ...........................................................................1in
Compressor .............................................................700BTU/hr
70°F
1-6 INSTALLATION
refrigerator for air circulation.
- 3 -
22cuft 423KWh/yr (Energy star)
90°F

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents