1. SPECIFICATIONS

1-1 DISCONNECT POWER CORD BEFORE
SERVICING
IMPORTANT RECONNECT ALL
GROUNDING DEVICES
All parts of this appliance capable of conducting electrical
current are grounded. If grounding wires, screws, straps,
clips, nuts or washers used to complete a path to ground
are removed for service, they must be returned to their
original position and properly fastened.
1-2 IMPORTANT NOTICE
This information is intended for use by individuals
possessing adequate backgrounds of electrical, electronic
and mechanical experience. Any attempt to repair a major
appliance may result in personal injury and property
damage. The manufacturer or seller cannot be responsible
for the interpretation of this information, nor can it assume
any liability in connection with its use.
1-3 ELECTRICAL SPECIFICATIONS
Temperature Control (Position : MID)........................ 8-(-6)°F
Defrost Control..............................................................Automatic.
Defrost Thermostat......................................................... 50°F
Electrical Rating :115V. AC, 60 Hz...........................1-5 Amp.
Maximum Current Leakage.........................................0.5 mA
Maximum Ground Path Resistance...................... 0.14 Ohms
Energy Consumption..
520kWh/yr (meet DOE)
530kWh/yr (meet DOE)
795.75004.402
795.75204.402
795.75002.402
795.75202.402
795.75009.402
795.75209.402
795.75014.402
795.75214.402
795.75012.402
795.75212.402
795.75019.402
795.75219.402
1-4 NO LOAD PERFORMANCE
CONTROL POSITION: MID/MID
And Ambient of :.........................70°F..........................90°F
Fresh Food, °F..............33°F to 41°F.............33°F to 41°F
Frozen Food, °F............ (-4°F) to 4°F............. ( -4°F) to 4°F
Percent RunningTime .......25%-35%.................45%-60%
PERFORMANCE DATA
(NORMAL OPERATING CONDITIONS)
AMB
WATTS
70°F
98 (+10 / -10)
90°F
98 (+10 / -10)
110°F
103 (+5 / -5)
1-5 REFRIGERATION SYSTEM
Minimum Compressor Capacity Vacuum ...................21 in.
Minimum Equalized Pressure
@ 70°F .......................................................49 PSIG
@ 90°F ....................................................... 56 PSIG
Refrigerant - R - 134a ............................................. 4.2 Oz
Compressor ......................................................700 BTU/hr
1-6 INSTALLATION
Clearance must be provided at top, sides and rear of the
refrigerator for air circulation.
AT TOP ........................................................................
AT SIDES ...................................................................1/8 in
AT REAR ......................................................................1 in
SYSTEM PRESSURE (PSIG)
HIGH SIDE
LOW SIDE
97 (+5 / -3)
(-5) to (-2)
130 (+3 / -3)
(-4) to 1
174 (+5 / -5)
(-2) to 3
1 in
1-7 REPLACEMENT PARTS
Relay.............................................................6749C-0008D
Overload .......................................................6750C-0004S
Defrost Thermostat...................................... 6615JB2005C
Defrost Heater.............................. 20cu. ft : 5300JB1100D
...............................22cu. ft : 5300JB1100J
Evaporator Fan Motor.................................. 4680JK1002B
Capacitor ....................................................OCZZJB2012J
Compressor (Hi-Side).................................. 2521CRA5715
Evaporator (Lo-Side)..................... 20cu. ft : 5421JJ1001A
.....................22cu. ft : 5421JJ1001B
Condenser ...............................................5403JJ1007A
Dryer .............................................................5851JJ2002B
Condenser Fan Motor ..................................4680JK1001B
Temperature Control.............................6871JB2047A
Main Control...........................................6871JB1215F
1-8 AIR FLOW / CIRCULATION D' AIR
EVAPORATOR FAN
DRYER
COMPRESSOR
21cu.ft............................................ 5.47 oz.
COLD AIR
MIXED AIR
AIR RETURN TO
EVAPORATOR
EVAPORATOR
- 3-
EVAPORATOR
HOT LOOP
CONDENSER FAN
CONDENSER
FRESH FOOD
V egetable box
FREEZER

Hide quick links: