1. SPECIFICATIONS

1-1 DISCONNECT POWER CORD BEFORE SERVICING IMPORTANT:
RECONNECT ALL GROUNDING DEVICES.
All parts of this appliance capable of conducting electrical current are grounded. If grounding wires, screws, straps, clips, nuts or washers
used to complete a path to ground are removed for service, they must be returned to their original position and properly fastened.
1-2 IMPORTANT NOTICE
This information is intended for use by individuals possessing adequate background of electrical, electronic and mechanical experience.
Any attempt to repair a major appliance may result in personal injury and property damage. The manufacturer or seller cannot be
responsible for the interpretation of this information, nor can it assume any liability in connection with its use.
1.3
E L E C T R IC A L S P E C IF IC AT IO N S
Freezer Temperature Control (Middle setting)
Defrost Control ...................................................................................................................................................................................Automatic
Defrost Thermostat .....................................................................................................................................................................................50°F
Electrical Rating : 115VAC, 60Hz...............................................................................................................................................................1- 5 A
Maximum Current Leakage .....................................................................................................................................................................0.5mA
Maximum Ground Path Resistance ..................................................................................................................................................0.14 Ohms
Energy Consumption ....................................................................................................................................22 cu.ft. 4 93 kWh/yr (Energy Star)
1-4 NO LOAD PERFORMANCE
C o n tr o l P o s it io n : M ID /M ID
And Ambient of:
Fresh Food, °F............................................................... 33°F to 41°F
Frozen Food, °F..............................................................
Percent Running Time........................................................
1-5 REFRIGERATION SYSTEM
Minimum Compressor Capacity Vacuum ...................................21 in
Minimum Equalized Pressure
@70°F......................................................................49PSIG
@90°F......................................................................56PSIG
Refrigerant R134a................................................................. 4.2 . oz
Compressor ................................................................... 700 BTU/hr
................................................................................................................... -6°F to +8 °F
70°F
......................................................................................
-4°F to +4°F
......................................................................................
...................................................................................... .
25%-35%
1-6 INSTALLATION
Clearance must be provided at top, sides and rear of the refrigerator
for air circulation.
AT TOP..........................................................................................1 in
AT SIDES.................................................................................. 1/8 in
AT REAR.......................................................................................1 in
- 3 -
90°F
33°F to 41°F
-4°F to +4°F
....
45%-60%