1. SPECIFICATIONS

1-1 DISCONNECT POWER CORD BEFORE
All parts of this appliance capable of conducting electrical
current are grounded. If grounding wires, screws, straps,
clips, nuts or washers used to complete a path to ground
are removed for service, they must be returned to their
original position and properly fastened.
1-2 IMPORTANT NOTICE
This information is intended for use by individuals
possessing adequate backgrounds of electrical, electronic
and mechanical experience. Any attempt to repair a major
appliance may result in personal injury and property
damage. The manufacturer or seller cannot be responsible
for the interpretation of this information, nor can it assume
any liability in connection with its use.
1-3 ELECTRICAL SPECIFICATIONS
Temperature Control (Freezer Compartment) .. -6°F to +8°F
Defrost Control .....Total Comp Running Time: 7 hrs~50 hrs
Defrost Thermistor ...................................................... 46°F
Electrical Rating : 115VAC, 60Hz ................................ 5.2 A
Maximum Current Leakage ...................................... 0.5 mA
Maximum Ground Path Resistance ................... 0.14 Ohms
Energy Consumption ........................................ 24 cu.ft. 750
1-4 NO LOAD PERFORMANCE
And Ambient of : ................ 70°F ................................. 90°F
Fresh Food, °F .................. 33°F to 41°F ........ 33°F to 41°F
Frozen Food, °F ................ -4°F to +4°F ......... -4°F to +4°F
Percent Running Time ...... 35%-45% ................. 50%-70%
1-5 REFRIGERATION SYSTEM
Minimum Compressor Capacity Vacuum ................ 21 MIN.
Minimum Equalized Pressure
Refrigerant R134a ................................................... 5.29 oz.
Compressor ..................................................... 1023 BTU/hr
1-6 INSTALLATION
Clearance must be provided at top, sides and rear of the
refrigerator for air circulation.
AT REAR ....................................................................... 2 in
SERVICING
IMPORTANT - RECONNECT ALL
GROUNDING DEVICES
CONTROL POSITION : MID/MID
@ 70°F ............................................................ 49 PSIG
@ 90°F ............................................................ 56 PSIG
1-7 REPLACEMENT PARTS
Defrost Heater ...............................................5300JK1005Z
Evaporator Fan Motor .................................. EAU60694512
Capacitor (Running) ..................................... EAE32501010
Compressor (Hi-Side) ................................... TCA35893202
Evaporator (Lo-Side) ..................................... ADL73762005
Condenser ................................................... ACG73749402
Dryer ............................................................. ADH69749103
Condenser Fan Motor ................................... 4681JB1029D
Temperature Control ...........................
Main Control ................................................. EBR74796445
Ice Fan Motor ............................................... EAU60694504
1-8 AIR FLOW / CIRCULATION D'AIR
- 3 -
24 cuft
795.70332.410
795.70333.410
795.70339.410
ACQ76217928(WB)
ACQ76217923(SW)
ACQ76217924(STS)