21. Mounting methods

By means of appropriate mounting accessories
the standard IED case for the 615 series IED can
be flush mounted, semi-flush mounted or wall
mounted. The flush mounted and wall mounted
IED cases can also be mounted in a tilted position
(25°) using special accessories.
Further, the IEDs can be mounted in any standard
19" instrument cabinet by means of 19" mounting
panels available with cut-outs for one or two
IEDs. Alternatively, the IED can be mounted in 19"
instrument cabinets by means of 4U Combiflex
equipment frames.
For the routine testing purposes, the IED cases
can be equipped with test switches, type RTXP
18, which can be mounted side by side with the
IED cases.
IECA070900 V4 EN
Figure 15.
Flush mounting

22. IED case and IED plug-in unit

For safety reasons, the IED cases for current
measuring IEDs are provided with automatically
Rows in the view
10
Mounting methods:
• Flush mounting
• Semi-flush mounting
• Semi-flush mounting in a 25° tilt
• Rack mounting
• Wall mounting
• Mounting to a 19" equipment frame
• Mounting with a RTXP 18 test switch to a
19" rack
Panel cut-out for flush mounting:
• Height: 161.5±1 mm
• Width: 165.5±1 mm
IECA070903 V4 EN
Figure 16.
Semi-flush mounting
operating contacts for short-circuiting the CT
secondary circuits when a IED unit is withdrawn
from its case. The IED case is further provided
1MRS756500 F
Characters per row
8
8 or more
IECA070902 V4 EN
Figure 17.
Semi-flush with a 25º
tilt
20
51