Selection And Ordering Data - ABB RED615 Product Manual

Line differential protection and control
Hide thumbs Also See for RED615:
Table of Contents

Advertisement

Line Differential Protection and Control
RED615
Product version: 4.0
with a mechanical coding system preventing
current measuring IED units from being inserted
into a IED case for a voltage measuring IED unit
and vice versa, i.e. the IED cases are assigned to
a certain type of IED plug-in unit.

23. Selection and ordering data

The IED type and serial number label identifies the
protection IED. The label is placed above the HMI
#
Description
1
IED
615 series IED (including case)
615 series IED (including case) with test switch, wired and in -
stalled in a 19" equipment panel
615 series IED (including case) with test switch, wired and in -
stalled in a mounting bracket for CombiFlex rack mounting (RGHT
19" 4U variant C)
2
Standard
IEC
3
Main application
Line di erential protection and control
GUID-4753ED2D-5A23-4F34-A689-9E47511ED8C7 V5 EN
The standard configuration determines the I/O hardware and available options.
The example below shows standard configuration "C" with chosen options.
#
Description
4-8
Standard configurations, analog and binary I/O options
Standard configuration descriptions in short:
A = Line-di erential protection, CB control and with the optional I/O module
control of two network objects
B = Line-di erential protection with directional earth-fault protection, CB condi -
tion monitoring, CB control and with the optional I/O module control of two
network objects
C = Line-di erential protection with non-directional earth-fault protection, CB
condition monitoring, CB control and with the optional I/O module control of
two network objects
Std. conf.
I/O options
A
4I (Io 1/5 A) + 12 BI + 10 BO
A
4I (Io 1/5 A) + 18 BI + 13 BO
B
4I (Io 1/5 A) + Uo + 11 BI + 10 BO
B
4I (Io 1/5 A) + Uo + 17 BI + 13 BO
B
4I (Io 0.2/1 A) + Uo + 11 BI + 10 BO
B
4I (Io 0.2/1 A) + Uo + 17 BI + 13 BO
C
4I (Io 1/5 A) + 12 BI + 10 BO
C
4I (Io 1/5 A) + 18 BI + 13 BO
* = The optional I/O module included
GUID-04EDC87A-1B36-4896-ACBA-5F4E5AAF91E7 V2 EN
52
on the upper part of the plug-in-unit. An order
number label is placed on the side of the plug-in
unit as well as inside the case. The order number
consists of a string of codes generated from the
IED's hardware and software modules.
Use the ordering key information to generate the
order number when ordering complete IEDs.
H B D
C A C A D B K C 1 B A N 1 X E
H
K
L
B
D
H B D
C A C A D
AACAD
AACAF*
BAAAC
BAAAE*
BABAC
BABAE*
CACAD
CACAF*
1MRS756500 F
B K C 1 B A N 1 X E