TwinSide TS™ Thermal Printer Family
Cutter:
Presenter:
Dimensions (WxHxD):
(with presenter)
Environmental Range
Operating:
Storage:

12.2. Electromagnetic Compatibility

12.2.1. FCC Part 15 Class A Device

NOTE- This equipment has been tested and found to comply with the limits for a
Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates uses and can radiate radio
frequency energy and, if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If this equipment
does cause harmful interference to radio or television reception, which can be
determined by tuning the equipment off and on, the user is encouraged to try to
correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which
the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
12.2.2. EN55022 – Emissions
The TwinSide TS™ family of thermal printers are Class "A" appliances, and comply to
applicable Class "A" standards, when installed in a properly grounded housing with
appropriate conductive shielding.
When operating the printer from a DC building power supply, or when the DC power
cable exceeds 3 meters in length, appropriate EMI filters must be used.
12.2.3. EN55024 – Electromagnetic Susceptibility
Electrostatic discharges and burst effects may cause short printing interruptions, but
the automatic recovery function of the printer will restore it to its original state.
Additional action regarding lightning and overvoltage protection will be needed if
cables and wires are installed outside of a building.
However, this standard can be met only if original units, components, and cables are
used and the installation instructions are respected and followed completely.
External interference caused by ESD or EMI can temporarily cause corrupted printing
or data loss.
Part No. D 691 023A
Full-cut Guillotine-type
Loop-type with retract
109 x 137 x 245 mm (approx.)
-25°C to -10ºC / 10% to 60% RH, non-condensing
>-10°C to <+50°C / 15% to 90% RH, non-condensing
+50°C to +70°C / 15% to 70% RH, non-condensing
-30°C to -10ºC / 10% to 60% RH, non-condensing
>-10°C to +75°C / 10% to 90% RH, non-condensing
Mod. No. 4 120912 LEV
HENGSTLER
page 33 of 34
®