Interfacing - Hengstler TS-56 Operating Manual

Twinside ts
Table of Contents

Advertisement

TwinSide TS™ Thermal Printer Family

5.4.2. Interfacing

Serial RS-232
The printer is shipped with the following serial settings as default: 115,200 baud, 8
data bits, one stop bit, no parity, hardware flow control, and host transmission not
blocked. (This last feature is intended for use with lower sophistication hosts that
cannot read the TwinSide TS™ printer's status data.
handshake lines to prevent the host from sending more data if the printer registers
"paper out".)
The serial versions of the TwinSide TS™ printer use an RJ12 connector (the female
connector is mounted in the printer, and the male in the cable) to make the RS-232
connection. Arrows represent whether the printer sends or receives the signal.
Hengstler can provide a serial cable for direct connection to PCs with a DB-9 female
connector on one end. Connections are shown below, should you wish to make your
own cables.
Part No. D 691 023A
Figure 10
Serial Pinout of TwinSide TS™ Printer
TS-56 RJ12F
Function Pin #
TX
1
RX
2
RTS
3
CTS
4
No conn. 5
Sig. Gnd. 6
Mod. No. 4 120912 LEV
HENGSTLER
It uses the hardware
page 22 of 34
®

Advertisement

Table of Contents
loading

Table of Contents