Chapter 6 Troubleshooting; Introduction - Motorola fx7400 Integrator Manual

Rfid readers
Hide thumbs Also See for fx7400:
Table of Contents

Advertisement

Chapter 6 Troubleshooting

Introduction

Table 6-1 on page 6-1
Troubleshooting
Troubleshooting
Table 6-1
Problem
Reader error LED lights after the
reader has been in operation.
Reader error LED stays lit on power
up.
Cannot connect to the reader.
Reader is not reading tags.
Cannot access the
Administrator
.
Console
provides the FX Series troubleshooting information.
Possible Causes
The CPU cannot
communicate.
An error occurred during the
power up sequence.
User name and password is
unknown.
1. The tag is out of its read
range
2. Antennas not connected
3. Tags are damaged
4. Tags are not EPCgen2
5. If reading with the
reader's web page, Java 1.6
or later may not be installed
The IP address is unknown.
Possible Solutions
Refer to the system log for error messages.
Refer to the system log for error messages.
The default user name is
admin
password is
. To change the user name and
change
password. See
Communications Connections on
page
3-6.
1. Move the tag into the read range. See
Tags on page
4-18.
2. Connect antennas
3. Confirm that tags are good
4. Confirm that tags are EPCgen2
5. Install Java 1.6. SeeJava Upgrade Procedures
on page C-1
See
Communications Connections on page 3-6
to view the IP address.
and the default
Read

Hide quick links: