NOTE
Entering invalid value
of parameter will re-
sult in response with
Application Rejected
frame and not setting
the value.
ADVANCED PARAMETERS

#9: Advanced parameters

The CO Sensor allows to customize its operation to user's needs. The
settings are available in the FIBARO interface as simple options that
may be chosen by selecting the appropriate box.
In order to configure the CO Sensor (using the Home Center controller):
1. Go to the device options by clicking the icon:
2. Select the „Advanced" tab.
3. Modify values of chosen parameters.
4. Save the changes.
5. Press the button to wake up the device.
Wake up interval
Available settings: 0 or 3600-43200 (in seconds, 1h - 12h)
Default setting: 21 600 (every 6 hours)
The CO Sensor will wake up at each defined time interval and always try
to connect with the main controller. After successful communication
attempt, the device will update configuration parameters, associations,
settings and then will go into Z-Wave communication standby.
After failed communication attempt (eg. no Z-Wave range) the device
will go into Z-Wave communication standby and retry to establish con-
nection with the main controller after the next time interval.
Setting wake up interval to 0 disables sending Wake up notification to
the controller automatically. Wake up may be still performed manually
using the button.
Longer time interval means less frequent communication and thus a
longer battery life.
2. Z-Wave notifications
This parameter allows to set the actions which result in sending noti-
fications to the Z-Wave network controller.
Available settings: 0 - both actions disabled
Default setting:
3. LED diode indications
This parameter allows to set the actions which result in LED diode
indications. This parameter does not apply to the most important ac-
tions, such as CO Alarm, Malfunction Alarm and Low Battery Alarm.
1 - tampering (opened casing)
2 - exceeding the temperature
3 - both actions enabled
0
Parameter size:
1 [byte]