6: Visual Indications & Acoustic Signals - FIBARO FGCD-001 Operating Manual

Co
Hide thumbs Also See for FGCD-001:
Table of Contents

Advertisement

8
i
NOTE
Replace the device be-
fore date on the front
or if sensor error is de-
tected.
VISuAL INDICATIONS & ACOuSTIC SIGNALS
#6: Visual indications & acoustic
signals
Indications and signals:
The CO Sensor is equipped with a LED diode and a buzzer, signalling
menu position and status of the device.
Device status indications:
What
What you see
you hear
4 x BEEP
4 x RED BLINK
every 5s
every 5s
1 x yELLOW BLINK
1 x BEEP
every 30s
1 x BEEP
every 30s
2 x CyAN BLINK
2 x BEEP
every 30s
3 x BEEP
1 x BLuE BLINK
every 30s
every 30s
1 x BEEP
1 x WHITE BLINK
1 x GREEN BLINK
after button press
1 x GREEN BLINK
1 x BEEP
after powering
1 x RED BLINK
1 x BEEP
after powering
1 x MAGENTA BLINK
1 x BEEP
every 10min
CyAN BLINKING
What it means
Detected pres-
ence of carbon
monoxide which
can kill you!
Low battery level
Sensor error
(does not detect
carbon monoxide)
End of lifespan
Heat alarm
Tamper alarm
Device powered
Added to Z-Wave
Not added to
Z-Wave
Out of range
Firmware update
What to do
1. Open the windows
2. Move to fresh air!
3. Contact emergency
services
Replace the battery
Reset the device,
replace if no effect
Reset the device,
replace if no effect
Be cautious of fire
Check the housing
Check the Z-Wave
range
Wait for completion

Advertisement