ADVAnCED PARAMETERS

#9: Advanced parameters

FIBARO Flood Sensor allows to customize its operation to user's needs.
The settings are available in the FIBARO interface as simple options
that may be chosen by selecting the appropriate box.
In order to configure FIBARO Flood Sensor (using the home Center
controller):
1. Go to the device options by clicking the icon:
2. Select the „Advanced" tab
Wake up interval (battery mode)
Available settings: 0 or 60-86400 (in seconds, 1min - 24h)
Default setting: 21 600 (every 6 hours)
FIBARO Flood Sensor will wake up at each defined time interval and
always try to connect with the main controller. After successful com-
munication attempt, a sensor will update configuration parameters,
associations and settings, and then will go into standby mode. After
failed communication attempt (eg. lack of Z-Wave range) the device
will go into standby mode and retry to establish connection with the
main controller after the next time interval.
Setting wake up interval to 0 disables sending Wake up notification
frame automatically. Wake up may be still performed manually by a
triple TMP button click.
Longer time interval means less frequent communication and thus a
longer battery life
1. Alarm cancellation delay
Determines time period, in seconds, by which a Flood Sensor will re-
tain the flood state after the flooding itself, has ceased. Sensor will
keep on reporting flooding to the main controller. This parameter set-
tings do not affect acoustic and visual alarms, which turn off immedi-
ately after flooding ceases.
Available settings: 0-3600 (in seconds, each 1s)
Default setting:
2. Acoustic and visual signals On / Off in case of flooding
The parameter allows for deactivation visual and acoustic alarm.
Parameter allows for increasing a battery life. Settings changes will
not affect the Sensors communication with the main controller - com-
mands to association groups, alarms and reports will still be sent.
0
Parameter size:
2 [bytes]