14
i
NOTE
Setting
parameters
11-12 to appropriate
value will result in:
0 - turning associated
devices off
1-99 - forcing level of
associated devices
255 - setting associat-
ed devices to the last
remembered state or
turning them on
i
NOTE
Parameter 14 value
must be at least 4 ppm
higher than parame-
ter 17 value.
i
NOTE
Setting parameter 16
to appropriate value
will result in:
0 - turning associated
devices off
1-99 - forcing level of
associated devices
255 - setting associat-
ed devices to the last
remembered state or
turning them on.
i
NOTE
Parameter 17 value
must be at least 4 ppm
lower than parameter
14 value.
ADVANCED PARAMETERS
12. Value of BASIC OFF command sent to 2nd association group
This parameter defines the value of BASIC OFF command sent to de-
vices in 2nd association group after the CO Alarm cancellation.
Available settings: 0-99 or 255
Default setting:
13. Commands sent to 4th association group (CO Level)
This parameter defines commands sent to devices associated in 4th
association group (CO Level). Values of specified commands may be
set in parameters 16 and 19.
Available settings: 1 - BASIC ON
Default setting:
14. CO level required for sending BASIC ON command to 4th as-
sociation group
This parameter defines the minimum level of CO concentration which
exceeding will result in starting the timer set in parameter 15.
Available settings: 25-400 - CO concentration level in ppm
Default setting:
15. Time required for sending BASIC ON command to 4th associ-
ation group
This parameter defines the time during which the level of CO concen-
tration should remain above the value set in parameter 14 to send the
BASIC ON command to 4th association group.
Available settings: 0 - immediate sending of BASIC ON command
Default setting:
16. Value of BASIC ON command sent to 4th association group
This parameter defines the value of BASIC ON command sent to de-
vices in 4th association group after exceeding the CO level set in pa-
rameter 14 through the time set in parameter 15.
Available settings: 0-99 or 255
Default setting:
17. CO Level required for sending BASIC OFF command to 4th as-
sociation group
This parameter defines the level of CO concentration below which
falling will result in sending the BASIC OFF command to 4th associa-
tion group.
Available settings: 10-400 - CO concentration level in ppm
Default setting:
0 (turn off )
Parameter size:
2 - BASIC OFF
3 - BASIC ON & BASIC OFF
3 (ON & OFF) Parameter size:
40 (40 ppm)
Parameter size:
1-2880 (30s - 24h, in 30s steps)
0
Parameter size:
255 (turn on) Parameter size:
25 (25 ppm)
Parameter size:
2 [bytes]
1 [byte]
2 [bytes]
2 [bytes]
2 [bytes]
2 [bytes]