5-3. S BOARD ADJUSTMENTS

@]
IC1101
T1101
S Board Adjusting Components Location

5-3-1. SECAM Bell Filter Adjustment (T1101)

Input signal:
SECAM color bars signal
Switches:
SYNC INT/EXT 8 INT
LINE/RGB
1. Connect an oscilloscope to pin 24 of IC1101.
2. Adjust T1101 (BELL FILTER) so that the envelope of
chroma signal is flat.
IC1101
PIN-24
5-3-2. SECAM Color Balance Adjustment
(L1102, L1103)
Input signal:
SECAM color bars signal
SYNC INT/EXT 8 INT
Switches:
LINE/RGB
1. Connect an oscilloscope to pin 9 of CN1101.
2. Adjust L1102 so that no chroma component (no
colored) portions of R-Y signal is flat.
R-Y
CN1101
PIN-9
3. Adjust L1103 so that no chroma component (no
colored) portions of B-Y signal is flat.
B-Y
CN1101
PIN-9
5-8
L1103
RV1101
RV1102
L1102
CN1101
9
8 LINE
8 LINE
5-3-3. SECAM Demodulation Level Adjustment
(RV1101, RV1102)
Input signal:
SECAM color bars signal
SYNC INT/EXT 8 INT
Switches:
LINE/RGB
1. Connect an oscilloscope to pin 30 of IC124 on the B
board.
2. Adjust RV1101 (SECAM COL) so that the peak level
difference of B signal is minimum (20 mVp-p or less).
Adjust so that the 1st and the 4th peaks should have the
same level.
IC124
PIN-30
(B BOARD)
3. Connect an oscilloscope to pin 41 of IC124 on the B
board.
4. Adjust RV1102 (SECAM R-Y) so that the level
difference of R signal is minimum.
Specification:
Level difference of B and D = Minimum (20 mV or less)
Level difference of B and C = Minimum (60 mV or less)
A
IC124
B
PIN-41
(B BOARD)
8 LINE
20 mVp-p or less
60 mV or less
C
D
20 mV or less
MIC