AP300 Plenum Requirements

When installing APs in an air-handling space, as described in Article 300.22(C) of the
NEC (2005), the unit should only be powered by the Ethernet port (PoE), not by the
AC-powered power supply.
When the product is installed in air-handling spaces, the cables employed should be
suitable under NEC Articles 300.22 and 725 and marked accordingly, for use in
plenums and air-handling spaces with regard to smoke propagation, such as CL2-P,
CL3-P, MPP or CMP.
The products should be installed in accordance with all applicable, local regulations
and practices.