Most installations receive the best coverage using the following guidelines:
Install APs toward the center of the building.
Place APs about 80 feet apart.
Do not install APs near metal objects, such as heating ducts, metal doors, or electric service panels.
If you install AP332i on a pole, keep in mind that coverage will be 180 degrees. Do not mount two
AP332is back to back on a pole to achieve 360 degree coverage, however, because the two units
could interfere with each other.

Install the Access Point

AP332i ships several different mounting bracket components to allow for a variety of mounting options.
You can mount an AP332i in the following ways:
Mount AP332i Horizontally on a Shelf
Mount AP332i Vertically on a Wall
Mount AP332i Below a Suspended Ceiling
Mount AP332i on a Dropped Ceiling Bevel Tile
Mount AP332i on an Interlude T-Bar
Mount AP332i Above a Suspended Ceiling
Mount AP332i Horizontally on a Shelf
When mounting an AP332i horizontally, simply place it on the desired surface and connect power and
network cables.
Mount AP332i Vertically on a Wall
The AP332 ships with a metal bracket that can be used to mount it on a wall. This bracket is used in
conjunction with the plastic 650-00232 15/16" T-Bar Adapter/Wall Mount bracket to easily lock the
AP into place.
To mount an AP332i on a wall:
1. Place the metal bracket against the wall. It should be oriented such that the indicator text for wall-
mounting is pointing upwards (see
© 2012 Meru Networks, Inc.
Figure
14).
Installing AP332i
Installing AP332i
23