Meru Networks AP332 Installation Manual page 39

Table of Contents

Advertisement

Mount AP332i on an Interlude T-Bar
The mounting procedure for a ceiling that has interlude T-Bar supports is similar to that of mounting
on a suspended ceiling. However, this procedure requires a specialized mounting bracket (MNT-
SCRMKIT-04), as depicted in
Figure 18: T-Bar Mounting Bracket
1. Remove the ceiling tile alongside which the AP will be mounted.
2. Locate the 650-00232 15/16" T-Bar Adapter/Wall Mount and attach the AP to the mounting
bracket by pressing the bracket's Mounting Pins (shown in
sliding the bracket until it locks in place.
3. Push down on the thumbscrews provided on the mounting bracket and clip it to the ceiling bar that
will support the AP.
4. Tighten the screws to ensure that the mechanism stays locked in place.
5. Gently press the underside of the AP (with bracket attached) against the T-Bar Mounting bracket
indicated above and twist to lock them together.
6. Connect one end of the CAT5 (or greater) Ethernet cable with PoE to the 100/1000 Ethernet
connector on the underside of the AP.
7. Verify that the AP comes online and then replace the ceiling tiles removed in Step 1.
Mount AP332i Above a Suspended Ceiling
Note:
© 2012 Meru Networks, Inc.
Figure
18.
AP332i is not plenum-rated and should only be mounted above ceilings in
non-plenum air space, such as a return airflow for air conditioning.
Installing AP332i
Figure
16) to the AP's Receiving Slots and
Installing AP332i
27

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents