Replacement Procedure

Note
 Do not expose the image drum unit to direct sunlight or
very bright interior light (approximately more than
1500lux). Even under the normal interior light, do not
leave it for more than 5 minutes.
Prepare the new fuser unit.
1
Turn off your machine.
2
Reference
 "Turning Off Your Machine" (P. 19)
Open the scanner unit.
3
Press the top cover open button (1) and
4
open the top cover.
Possible to get
CAUTION
 Since the fuser unit gets hot, carry out the
operation carefully, and when lifting it up you
must hold it by the handle. Do not try to hold it
whilst it is hot. Wait until it has cooled down and
then carry out the operation.
1
Pull the locking levers (2) on each side of
5
the fuser unit to unlock.
2
burned.
2
- 167 -
Hold the fuser unit handle (3) and lift the
6
fuser unit out of the machine.
Unpack the replacement fuser unit.
7
Remove the orange stopper (5) while
8
pressing the blue lever (4) of the fuser
unit in the direction of the arrow.
Note
 Keep the orange stopper. It is necessary to transport
the machine.
Hold the fuser unit handle and place the
9
fuser unit into the machine.
Push the locking levers (6) on each side
10
of the fuser unit to lock.
6
Close the top cover.
11
Close the scanner unit.
12
Memo
 If you dispose of a toner cartridge by necessity, put it in a
polyethylene bag or something and then dispose of it in
accordance with your municipality's ordinances or guidelines.