Oki Data CONFIDENTIAL
1.2 Parts Replacement procedure
This Section contains the parts replacement for parts and assemblies.
1.2.1 Board-GOH-12 etc
Remove the two screws (Silver,No:41723901)
(1)
Joint ② ,and remove the Option Tray from MFP.
(2) Remove the cassette ③ from Option Tray Unit.
②
③
(3) R e m o v e t h e t w o s c r e w s ( B l a c k , N o : 4 2 9 3 2 7 0 8 ) ④ , a n d s i x
screws(Silver,No:42920406) ⑤ ,and remove the Cover-Side-L ⑥ and Cover-
Side-R ⑦ .
(4) Remove the three screws (silver) ⑧ and the two screws(black) ⑨ , and remove
the Plate-Joint ⑩ .
(5) Remove the four screws (silver) ⑪ and remove the Plate-Top ⑫ .
(6) Remove the two screws (black) ⑬ , and remove the Cover-Front ⑭ .
(7) Remove the four screws (black) ⑮ , and remove the Hopping-Assy ⑯ .
(8) Remove the two screws (silver) ⑰ , and remove the Board-GOH-12 ⑱ .
(9) Remove the two screws (shoulder) ⑲ , and remove the Connector ⑳ .
(10) Remove the screw (black) , and remove the Switch .
(11) Remove the two screws (black) , and remove the Connector .
45479001TH Rev.1
① and remove the
①
②
⑧
⑩
⑪
⑪
⑫
⑪
⑮
×4
⑯
⑰
×2
⑱
⑤
×3
⑥
⑬
×2
⑭
1. REPLACEMENT OF PARTS
⑨
⑧
⑩
⑲
×2
⑳
㉑
㉒
⑤
×3
⑦
㉓
㉔
×2
④
×2
7 /