3) Replace Rollers Display
Once the number of sheets fed exceeds
the guide for replacement of 200,000
sheets,
a
screen
message [Replace Rollers] is displayed
the next time the computer recognizes
the machine.
Figure 4-303
4) Method for Replacing Rollers
Feed roller
Open the roller cover and remove the
roller. Then assemble the new roller with
the stopper on the left side facing the
correct way.
Figure 4-304
Figure 4-305
COPYRIGHT © CANON ELECTRONICS INC. 2011
CHAPTER 4 INSTALLATION & MAINTENANCE
displaying
the
CANON DR-M160 FIRST EDITION
Retard roller
Open the roller cover and remove the
roller
by
pulling
assemble the new roller by inserting the
gear side to the main body first.
Figure 4-306
Figure 4-307
Figure 4-308
5) Resetting after replacement
The counters need to be reset after
replacing the rollers. The following
shows the method for doing this.
Start
Windows,
administrator privileges.
Click the [Start] button on the computer,
and then click [All Programs], [Canon
DR-M160], and [Canon imageFORMULA
Utility] in order.
The [Canon imageFORMULA Utility]
starts, and the screen is displayed.
the
lever.
Then
and
login
with
4-7