Displaying The Module Status - Brocade Communications Systems FastIron SX Hardware Installation Manual

Table of Contents

Advertisement

Verifying proper operation
TABLE 20 Desired and abnormal LED states after system power-on. (continued)
LED
DC OUT
ALM
If a problem persists after taking action described in this table, contact Brocade's technical support.

Displaying the module status

After you have attached a PC or terminal to the management module's Console port or Ethernet port and the Brocade device has
initialized successfully, press Enter to display the following CLI prompt in the terminal emulation window.
FastIron>
If you do not see this prompt, complete the following steps.
1.
Make sure the cable is securely connected to your PC or terminal and the Console port or Ethernet port.
78
Desired State
ON - Green (steady)
OFF
Meaning
The power supply is
supplying DC output power
to the chassis
No alarms present and the
power supply is in normal
operating condition.
Abnormal State
OFF
Amber
Brocade FastIron SX Series Chassis Hardware Installation Guide
Meaning or Action
The power supply is not
supplying DC output power
to the chassis.
If this occurs and the AC
OK (AC power supply) or
DC IN (DC power supply)
LED is Green, then there is
a problem with the power
supply and it must be
replaced.
There is an alarm present
and the power supply is
malfunctioning.
Verify the AC or DC input
and DC output voltages.
Part Number: 53-1003613-04