To replace the air filter in the FastIron SX-1600, perform the following tasks.
1.
Loosen the captive fasteners in the front of the filter retainer.
2.
Pull the filter retainer away from the chassis as shown in the figure above.
There is a hook on the back of the retainer that is attached to the grab-strap. As you pull the retainer out, the filter is pulled along
with it.
3.
Unhook the filter retainer from the air filter and discard the used filter.
4.
Partially insert the replacement air filter (part number 11211-401) by sliding it along the metal guides.
The filter is marked with an arrow. The arrow indicates how the filter should be installed in regards to the direction of airflow in
the chassis. Since air is pulled through the chassis, the arrow must point up towards the fan tray.
5.
Attach the hook on the back of the filter retainer to the filter grab-strap.
6.
Push the filter retainer into the chassis and tighten the captive fasteners.

Mean time between failure

The table below lists the Mean Time Between Failure (MTBF) for the FastIron X Series chassis devices and modules. The MTBF is the
average estimated time, in units of hours, before a hardware failure may occur.
TABLE 28 MTBF for the FastIron X Series chassis and modules
Configuration or Module
FSX
FSX chassis + fan module + backplane
FSX chassis + fan module + backplane + one AC
power supply
FSX chassis + fan module + backplane + one DC
power supply
AC power supply (non-POE supply)
AC POE power supply
DC power supply
FSX Management Modules
IPv6 Management Module with 256 MB
SDRAM and no optics
IPv6 Management Module with 256 MB
SDRAM and 12 optics
IPv6 Management Module with 512 MB
SDRAM and no optics
IPv6 Management Module with 512 MB
SDRAM and 12 optics
IPv4 Management Module with no optics
IPv4 Management Module with 12 optics
SX-FI-2XGMR-XL and the SX-FI-2XGMR-XL-
PREM6 management modules
FSX 800
FSX 800 + fan module + two switch fabric
modules
Brocade FastIron SX Series Chassis Hardware Installation Guide
Part Number: 53-1003613-04
Temperature
40 ° C
40 ° C
40 ° C
40 ° C
40 ° C
40 ° C
40 ° C
40 ° C
40 ° C
40 ° C
40 ° C
40 ° C
40 ° C
40 ° C

Mean time between failure

MTBF (hours)
1,003,172
269,386
272,432
368,282
139,000
374,000
292,557
211,053
287,425
208,369
287,664
152,154
506,155
230,584
155