Determining Management Module Status - Brocade Communications Systems FastIron SX Hardware Installation Manual

Table of Contents

Advertisement

Monitoring management module redundancy
The switchover history for the management modules
The following sections explain how you can monitor the management modules

Determining management module status

You can determine the status of a management module in the following ways:
LEDs - The LEDs on the management module indicate whether a module is the active module or the standby module, and if
the module has power.
Redundant management and module information in software - The module information displayed by the software indicates
whether a module is the active module or the standby module.
Status LED
If you are located near the chassis, you can determine which management module is currently the active module and which is the
standby module by observing the Active LED on each module. If this LED is on (green), the module is the active module. If this LED is
off, the module is the standby module.
You can also observe the Pwr LED on each module. If this LED is on (green), the module is receiving power. If this LED is off, the module
is not receiving power. (A module without power will not function as the active or standby module.)
Software
You can use the show module CLI command to display the status of the management modules.
The following shows an example output of the show module command.
device# show module
Module
F1: SX-FISF Switch Fabric
F2: SX-FISF Switch Fabric
S1: SX-FI-24GPP 24-port Gig Copper + PoE+
S2: SX-FI-8XG 8-port 10G Fiber
S3: Reserved
S4: SX-FI-8XG 8-port 10G Fiber
S5: SX-FI-48GPP 48-port Gig Copper + PoE+
S6:
S7:
S8:
S9: SX-FIZMRXL6 0-port Management
{ Status : OK }
S10:
Syntax: show module
The Status column indicates the module status. The management modules can have one of the following statuses:
ACTIVE - The module is currently the active management module.
STANDBY - The module is the standby management module. The status of the standby module can be one of the following:
Init - The module is currently initializing as the standby module.
OK - The module is ready to take over as the active module, if necessary.
Wait - The module is awaiting boot information from the active management module.
Sync - The active module is currently synchronizing files between itself and the standby module.
116
Status
Ports
active
active
OK
24
0024.3821.7500
OK
8
0024.3821.7518
OK
8
0024.3821.7548
OK
48
0024.3821.7500
Active
0
Standby
0
Brocade FastIron SX Series Chassis Hardware Installation Guide