Displaying The Status Of The Power Supplies; Replacing The Fsx 800 Fan Tray - Brocade Communications Systems FastIron SX Hardware Installation Manual

Table of Contents

Advertisement

TABLE 27 Desired and abnormal power supply LED states after system power on (continued)
LED
ALM
If a problem persists after taking action described in this table, contact Brocade's technical support.

Displaying the status of the power supplies

You can display the status of the power supplies by entering the show chassis command at any level of the CLI. The display shows
whether a power supply is installed in the specified power supply slot and the status of the power supply, which can be one of the
following:
OK - The power supply is functioning properly and supplying power to the chassis and installed modules.
Failed - The power supply is not functioning and is not supplying power to the chassis and installed modules.

Replacing the FSX 800 fan tray

The fan tray in the FSX 800 chassis contains six fans and one fan control module. If any of these components fail, you must replace the
entire fan tray.
NOTE
The fan tray in the FSX 800 chassis is a non-redundant, hot-swappable fan tray.
NOTE
The FSX 800 chassis should not be left running without a fan tray. This will lead to an increase in the chassis temperature, and
can result in a thermal shutdown.
To replace the fan tray, you need the following:
A new fan tray, which you can order from Brocade
In addition to the above, you might also need a #2 Phillips-head screwdriver.
DANGER
For safety reasons, the ESD wrist strap should contain a series 1 megaohm resistor.
To replace the fan tray, perform the following tasks.
1.
Put on the ESD wrist strap and ground yourself by inserting the plug into the ESD connector located in the lower right corner of
the chassis front or use the ESD strap provided with the fan tray kit. Attach the copper tape end to a bare metal area on the
chassis.
Brocade FastIron SX Series Chassis Hardware Installation Guide
Part Number: 53-1003613-04
Desired State
OFF
Desired State Meaning
No alarms present and the
power supply is in normal
operating condition.
Abnormal State
Amber

Replacing the FSX 800 fan tray

Abnormal State Meaning or
Action
supply and it must be
replaced.
There is an alarm present
and the power supply is
malfunctioning.
Verify the AC or DC input
and DC output voltages.
149