B-ALU Extern 180 Instructions For Installation And Use Manual page 60

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 42
7.4.2.
Safety equipment and devices
Press P3 twice – open the menu for configuring "Safety equipment"
Press P2 once – choose the menu for configuring "Safety equipment"
Sub-menu options
- change the settings with "PROG/OK"
- move with P1 or P3 up and down in the menu
TB CONTACT
Defines the function of the terminal 23
Normally closed contact (jumper set)
NC
Connection of a safety contact strip 8.2 KΩ
8K2
Defines the function of the terminal 26
FI CONTACT
Normally closed contact (jumper set)
NC
Connection of a safety contact strip 8.2 KΩ
8K2
FS CONTACT
Defines the function of the terminal 25
Normally closed contact (jumper set)
NC
Connection of a safety contact strip 8.2 KΩ
8K2
CP CONTACT
Defines the function of the terminal 24
Normally closed contact (jumper set)
NC
Connection of a safety contact strip 8.2 KΩ
8K2
OUTPUT
Exit the "Safety devices" menu
By pressing the P2 "PROG/OK" button, you return to
OK
the main menu of the "Safety devices" menu item
7.4.3.
Movement
Press P3 three times – open the menu for configuring "Movement"
Press P2 once – choose the menu for configuring " Movement"
Sub-menu options
- change the settings with "PROG/OK"
- move with P1 or P3 up and down in the menu
MOTOR SELECTION
Defines the motor type
i924 ESY
No function assigned
i924 ESB 700 kg
Maximum tensile and compressive force of 700 kg
i924 ELB 1000 kg
Maximum tensile and compressive force of 1,000 kg
CURRENT SENSOR
Adjusting the drive force
LEVEL 1...5
Each level increases the max. current consumption and
thus, the force of the drive by 1 ampere (Level 1 = + 2A)
RESTRICTED OPENING
Defines the proximity to the posts at the time of closure
METER 1...9
The opening width of the pedestrian opening can be set
from 1 to 9 metres here.
CLEARANCE FOR
Defines the proximity to the posts at the time of closure
CLOSING
The clearance can be changed from 0 – 6 cm in 9 steps.
0...4...9 STEPS
Default factory setting is "4" = 1 cm clearance
TIME FOR PAUSE
Defines the duration of automatic closure
If automatic closure operation is enabled in the "Options"
000...240 sec.
menu, this sets the time for which the gate is kept open
RESET PARAMETERS
Load the default factory settings
Resets the controller to the default factory settings. Only
OK
the language selected remains.
OUTPUT
Exit the "Movement" menu
By pressing the P2 "PROG/OK" button, you return to the
OK
main menu of the "Movement" menu item
ENGLISH