Function of the key switch
DYNAMIC BUTTON
Defines the function of the terminal 21 (potential-free)
Open – Stop – Close – Stop
OPEN-CLOSE.
Opens with pulse blocking – Close - Open
OPEN-STOP-CLOSE
Automatic closure
AUTO RECLOSURE
Switches automatic closing operation on or off
Automatic closing operation after the specified time
ON
Automatic closing operation disabled
OFF
Advanced flashing of the flashing lamp
Enables advanced flashing of a flashing lamp connected to
ADV. FLASHING
terminal 12
2 x advanced flashing of the flashing lamp
ON
The drive starts immediately without any advanced flashing
OFF
Function of the flashing lamp
FLASHING LAMP
Defines the function of the flashing lamp connected to terminal
12 (potential-free)
LIT UP CONTINUOUSLY
The lamp is list continuously during the movement
FLASHING
The lamp flashes while the gate is moving
Function of the pilot lamp
PILOT LAMP
Defines the function of the pilot lamp connected to terminal 13
Continuous illumination of the pilot lamp
Flashing as described under "Terminal assignment"
LIT UP CONTINUOUSLY
FLASHING
Function of the light barrier
REVERSAL OF
Defines the function of the safety device connected to terminal
26
PHOTOCELL
Reversal of movement when the safety device gets triggered
Pulses are blocked as long as the safety feature is enabled
WHEN CLOSING
ALSO WHEN STOPPING
Monitoring the safety
TEST FI
Enables monitoring of the safety device connected to
terminal 26
Monitoring active
ON
Monitoring not active
OFF
0
TEST FI
Enables monitoring of the safety device connected to
terminal 25
ON
Monitoring active
OFF
Monitoring not active
Direction of rotation of the motor
MOTOR INSTALLATION
Defines the direction of rotation of the motor
Drive installed on the left side as seen from inside
LEFT
Drive installed on the right side as seen from inside
RIGHT
Pulse and radio operation or dead man's operation
MANUAL
Pulse operation or dead man's mode
Dead man (terminals 18/19 must remain pressed)
ON
Pulse operation / self hold
OFF
Enable remote learning from the hand-held transmitter
REMOTE SAVING
Learning of other hand-held transmitters via radio
Learning activated via radio
ON
Deactivated, possible only via the remote menu
OFF
Wireless channel or ambient lamp
OUTPUT LC/CH2
Defines the function of the terminals 9 – 10
Pick-up of the 2nd Remote channel
WIRELESS CHANNEL
Ambient lamp with external supply (max. 30 V ac/dc,
WATCH LIGHT
1A)
Exit "Options"
OUTPUT
Exit the "Options" menu
By pressing the P2 "PROG/OK" button, you return to
OK
the main menu of the "Options" menu item