B-ALU Extern 180 Instructions For Installation And Use Manual page 51

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 42
3.6.2.
Inline
STEP
1
Put the photocells in place. Connect the photocells to the motor
using a cable.
3
STEP
ATTENTION!
DANGER TO LIFE by
electric current!
1. Check whether
the system is
electrically
deenergized. Next,
plug in the power
supply cable in the
control column according to the regulations applicable to the
power source.
2. Bring the gate to the middle position.
3. Remove the cover in the control column from the controller
and check the fuses.
5
STEP
Latch the motor and
drive the gate to the
closed position.
7
STEP
1. Check whether all
parts are working
smoothly and
properly.
2. Open the control
columm via the lock
on the outside of the
pillar.
3. Plug in the
connector of the rechargeable battery into the j1 jack at the top
right side on the control board.
ATTENTION! The gate also works if the mains supply is discon-
nected on rechargeable battery mode – crushing hazard – for
out-of-order position, also remove the plug to the
rechargeable battery!
2
STEP
Check once again
whether the end stop is
in the correct position:
The gate must be able to
open and close
completely, but in such a
manner that the safety
contact strip is located
ten millimetres away from the edge of the catcher post
ATTENTION! Crushing hazard!
4
STEP
Put the warning sign
stickers in place.
6
STEP
1. Insert the main plug
into the power supply.
2. After closing the gate,
program the system in
accordance with the
instructions furnished on
the motor.
ENGLISH
10

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Inline 160Inline 100Inline 120Inline 250

Table of Contents