B-ALU Extern 180 Instructions For Installation And Use Manual page 57

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 42
7.2. Terminal assignment
1 – 2
MOT
3 – 6
ENC
7
LCK
8
CMN
9 – 10
LC/CH2
11
CMN
12
LP
13
LS
14
CMN
15
CTRL24Vdc
16
CMN
17
OUT24Vdc
18
TA
19
TC
20
TAL
21
TD
22
CMN
23
TB
24
CP
25
FS
26
FI
27
ANT
28
ANT
29
CMN
30
EMRG1
31
EMRG2
In this way, the controller has saved the end potition
and the operating forces that are necessary. If
„PROGRAM" flashes on the display, the learning
operation must be restarted.
Motor connection (made at the factory)
Encoder connection (3 – blue/ 4 – green / 5 – grey / 6 – yellow) (done at the factory)
Emergency unlocking ("Motor free" text on the display)
Common connection
Connection of an externally powered ambient lamp (max. 30 V sc/dc, 1A) or pick-up 2. wireless
channel (potential-free switching contact)
Common termination
Flashing lamps (24 V dc / max. 25 W flashing or 12.5 W continuously)
Pilot lamp "Gate open" (24 V dc / max. 3 W)
It flashes slowly while opening and flashes quickly while closing.
It lights up continuously if the gate is blocked while closing.
It goes off when the gate is closed.
Common connection
24 V dc for feeding the monitored light barrier transmitter
Common connection
24 V dc for feeding the light barrier receiver
ATTENTION! Terminals 15 + 17 should be loaded with max. 10 W!
Defined opening command
Defined closing command
Partial opening (1-9 m programmable)
Dynamic starting pule
Opening with pulse blocking until the gate opens, and pulse when the closure opens
Opening – Stopping – Closing - Stopping
Common connection
Emergency stop / Connecting the safety contact strip
Reversing safety device / Connecting the safety contact strip
Stopping light barrier connection in the closing operation
After release, the quick movement is continued / connecting the safety contact strip
Reversing safety device in closing operation / Connecting the safety contact strip
Antenna connection (Signal) (RG 58 / 50 Ω)
Antenna connection (Sheath)
Common connection for emergency operation
Operates the gate in which the controller is bypassed
If the drive is on the left side, the gate is closed, and with the drive on the right side it is opened
Operates the gate in which the controller is bypassed
If the drive is on the left side, the gate is opened, and with the drive on the right side it is closed
ENGLISH
16

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Inline 160Inline 100Inline 120Inline 250

Table of Contents